[ 제품 문의하기 / Request ]
제품 가격 및 정보에 대하여 문의가 필요하신 분은 아래 버튼을 클릭하여 주세요.
For inquiries about product prices and information, please click the button below.
The Gamma-Spect-2×2 is a camera-core for hyperspectral x-ray and gamma-ray imaging. The device has 26-cm2 sensitive area (5.1cm x 5.1cm) and 1.6-mm spatial resolution (pixel pitch of 1.6mm). The sensitive area is pixelated with 1024 pixels (32 x 32). Each pixel is sensitive to x-rays and gamma-rays in the energy range from 20keV to 700keV with about 6keV FWHM energy resolution. The device can be fitted with various collimators to provide imaging capability (pin-holes, coded-apertures, and all types of multiple hole collimators).
제품 설명
The Gamma-Spect-2×2 is a camera-core for hyperspectral x-ray and gamma-ray imaging. The device has 26-cm2 sensitive area (5.1cm x 5.1cm) and 1.6-mm spatial resolution (pixel pitch of 1.6mm). The sensitive area is pixelated with 1024 pixels (32 x 32). Each pixel is sensitive to x-rays and gamma-rays in the energy range from 20keV to 700keV with about 6keV FWHM energy resolution. The device can be fitted with various collimators to provide imaging capability (pin-holes, coded-apertures, and all types of multiple hole collimators).
The Gamma-Spect-2×2 camera-core is based on cadmium zinc telluride (CZT) radiation sensors. The sensor can be operated at room temperature without cooling. Each sensor pixel is read out by charge sensitive amplifiers implemented on an integrated circuit.
The Gamma-Spect-2×2 camera-core can be mounted in any orientation and can be combined with more units to build systems with larger sensitive area or curved geometry.
The Gamma-Spect-2×2 connects to external systems via a standard Ethernet network interface.
Please contact us for more information.
Product Features
Applications and technologies | Hyperspectral x-ray and gamma-ray imaging, single photon counting, energy resolved counting, photon timing, energy spectroscopy, imaging. For: science, nuclear science, x-ray scanning, gamma-spectroscopy, nuclear medicine, pre-clinical research |
Sensitive area | 26-cm2 (5.1cm x 5.1cm) |
Intrinsic spatial resolution | 1.6 mm pixel pitch |
Number of pixels | Available options: 256 (16x16) to 1024 (32x32) |
Sensor material | CZT |
Energy range | Two options 20 keV to 350 keV, and 20 keV to 700 keV |
Energy resolution | 6keV full-width half maximum (FWHM) |
Trigger threshold | Programmable |
Data interface | List mode digital data via Ethernet UDP/IP |
Power | 8W |
Size of the sensor unit | 80 x 80 x 50 mm (L x W x D) |
Size of the readout unit | 175 x 71 x 80 mm (L x W x D) |
Weight | 1.5 kg |
Data interface | List mode digital data via Ethernet UDP/IP |
Energy range | Two options 20 keV to 350 keV, and 20 keV to 700 keV |
Sensitive area | 26-cm2 (5.1cm x 5.1cm) |
Number of pixels | Available options: 256 (16x16) to 1024 (32x32) |
Power | 8W |
배송안내
배송 지역 | 대한민국 전지역
배송비 | 2,500원 (50,000원 이상 결제시 무료배송)
배송기간 | 주말 공휴일 제외 2~5일
- 모든 배송은 택배사 사정으로 지연될 수 있습니다.
교환 및 반품 안내
- 고객 변심으로 인한 교환/반품은 상품 수령 후 14일 이내 가능합니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
- 반품접수 기한이 지난 경우, 제품 및 패키지 훼손, 사용 흔적이 있는 제품은 교환/반품이 불가합니다.
제품 설명
The Gamma-Spect-2×2 is a camera-core for hyperspectral x-ray and gamma-ray imaging. The device has 26-cm2 sensitive area (5.1cm x 5.1cm) and 1.6-mm spatial resolution (pixel pitch of 1.6mm). The sensitive area is pixelated with 1024 pixels (32 x 32). Each pixel is sensitive to x-rays and gamma-rays in the energy range from 20keV to 700keV with about 6keV FWHM energy resolution. The device can be fitted with various collimators to provide imaging capability (pin-holes, coded-apertures, and all types of multiple hole collimators).
The Gamma-Spect-2×2 camera-core is based on cadmium zinc telluride (CZT) radiation sensors. The sensor can be operated at room temperature without cooling. Each sensor pixel is read out by charge sensitive amplifiers implemented on an integrated circuit.
The Gamma-Spect-2×2 camera-core can be mounted in any orientation and can be combined with more units to build systems with larger sensitive area or curved geometry.
The Gamma-Spect-2×2 connects to external systems via a standard Ethernet network interface.
Please contact us for more information.
Product Features
Applications and technologies | Hyperspectral x-ray and gamma-ray imaging, single photon counting, energy resolved counting, photon timing, energy spectroscopy, imaging. For: science, nuclear science, x-ray scanning, gamma-spectroscopy, nuclear medicine, pre-clinical research |
Sensitive area | 26-cm2 (5.1cm x 5.1cm) |
Intrinsic spatial resolution | 1.6 mm pixel pitch |
Number of pixels | Available options: 256 (16x16) to 1024 (32x32) |
Sensor material | CZT |
Energy range | Two options 20 keV to 350 keV, and 20 keV to 700 keV |
Energy resolution | 6keV full-width half maximum (FWHM) |
Trigger threshold | Programmable |
Data interface | List mode digital data via Ethernet UDP/IP |
Power | 8W |
Size of the sensor unit | 80 x 80 x 50 mm (L x W x D) |
Size of the readout unit | 175 x 71 x 80 mm (L x W x D) |
Weight | 1.5 kg |
Data interface | List mode digital data via Ethernet UDP/IP |
Energy range | Two options 20 keV to 350 keV, and 20 keV to 700 keV |
Sensitive area | 26-cm2 (5.1cm x 5.1cm) |
Number of pixels | Available options: 256 (16x16) to 1024 (32x32) |
Power | 8W |
배송안내
배송 지역 | 대한민국 전지역
배송비 | 2,500원 (50,000원 이상 결제시 무료배송)
배송기간 | 주말 공휴일 제외 2~5일
- 모든 배송은 택배사 사정으로 지연될 수 있습니다.
교환 및 반품 안내
- 고객 변심으로 인한 교환/반품은 상품 수령 후 14일 이내 가능합니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
- 반품접수 기한이 지난 경우, 제품 및 패키지 훼손, 사용 흔적이 있는 제품은 교환/반품이 불가합니다.
[ 연관상품 ]