12-channel charge sensitive preamplifer-shaper circuit with programmable peaking time from 0.75 µs to 4 µs and current compensation on each input. The dynamic range is from 0 to -5.43 fC which covers 3.5 keV to 140 keV in CdTe/CZT. The shaper is connected to a comparator with adjustable threshold settings. When the signal out from the shaper exceeds the comparator threshold a trigger signal is generated. Upon trigger the ASIC delivers a package containing the triggering channel address and a value proportional to the energy of the deposited charge. The ASIC is then automatically reset, and is ready for the next radiation event.The countrate of the ASIC is up to 100 kcps.
Keywords: Radiation detector, X-ray single photon spectroscopy
| Detectors | CZT, CdTe |
| Detectors | CZT, CdTe |
| Application | Counting, Spectroscopy |
| Number of inputs | 12 |
| Input charge range | 12 0 fC to -5.14 fC |
| Shaping time | 0.75 µs to 4 µs programmable |
| Nominal capacitive load | 4 pF |
| Equivalent Noise Charge (ENC) | 110e |
| Trigger threshold | Adjustable |
| Outputs | Multiplexed differential current and a digital interface for triggered readout packages. |
| Test and calibration | Internal calibration circuit for gain calibration. |
배송안내
배송 지역 | 대한민국 전지역
배송비 | 2,500원 (50,000원 이상 결제시 무료배송)
배송기간 | 주말 공휴일 제외 2~5일
- 모든 배송은 택배사 사정으로 지연될 수 있습니다.
교환 및 반품 안내
- 고객 변심으로 인한 교환/반품은 상품 수령 후 14일 이내 가능합니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
- 반품접수 기한이 지난 경우, 제품 및 패키지 훼손, 사용 흔적이 있는 제품은 교환/반품이 불가합니다.

12-channel charge sensitive preamplifer-shaper circuit with programmable peaking time from 0.75 µs to 4 µs and current compensation on each input. The dynamic range is from 0 to -5.43 fC which covers 3.5 keV to 140 keV in CdTe/CZT. The shaper is connected to a comparator with adjustable threshold settings. When the signal out from the shaper exceeds the comparator threshold a trigger signal is generated. Upon trigger the ASIC delivers a package containing the triggering channel address and a value proportional to the energy of the deposited charge. The ASIC is then automatically reset, and is ready for the next radiation event.The countrate of the ASIC is up to 100 kcps.
Keywords: Radiation detector, X-ray single photon spectroscopy
| Detectors | CZT, CdTe |
| Detectors | CZT, CdTe |
| Application | Counting, Spectroscopy |
| Number of inputs | 12 |
| Input charge range | 12 0 fC to -5.14 fC |
| Shaping time | 0.75 µs to 4 µs programmable |
| Nominal capacitive load | 4 pF |
| Equivalent Noise Charge (ENC) | 110e |
| Trigger threshold | Adjustable |
| Outputs | Multiplexed differential current and a digital interface for triggered readout packages. |
| Test and calibration | Internal calibration circuit for gain calibration. |