33-channel and high dynamic range charge sensitive preamplifier-shaper circuit, with sample and hold, multiplexed analog readout and calibration facilities. Parallel analogue output of all 33 pre-amplifiers. Compatible with parallel connection to 32 channels TA-ASICs.
Publications
Torii, S., et al., “Development of front-end electronics with large dynamic range for space applications.” Nuclear Physics B-Proceedings Supplements 150 (2006): 390-393, doi:10.1016/j.nuclphysbps.2004.08.047
S. Marrocchesi, P., et al. “A silicon array for cosmic-ray composition measurements in CALET.” Journal of the Physical Society of Japan 78.Suppl. A (2009): 181-183, doi:10.1143/JPSJS.78SA.181
Marrocchesi, P. S., https://www.researchgate.net/publication/253124469_Polar_balloon_flights_with_a_scaled_version_of_CALET, Memorie della Societa Astronomica Italiana 79 (2008): 829, source: SAIT
| Detectors | Multi-anode photomultiplier (MA-PMT) |
| Application | Imaging, Spectroscopy, Calorimetry |
| Number of inputs | 33 |
| Input charge range | -20 pC to +8 pC |
| Shaping time | 2 μs |
| Equivalent Noise Charge (ENC) | 5200e + 5e/pF |
| Outputs | Multiplexed pulse height and individual output per channel |
| Test and calibration | Internal calibration circuit and test channel |
| Power consumption | 3.4 mW / channel |
배송안내
배송 지역 | 대한민국 전지역
배송비 | 2,500원 (50,000원 이상 결제시 무료배송)
배송기간 | 주말 공휴일 제외 2~5일
- 모든 배송은 택배사 사정으로 지연될 수 있습니다.
교환 및 반품 안내
- 고객 변심으로 인한 교환/반품은 상품 수령 후 14일 이내 가능합니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
- 반품접수 기한이 지난 경우, 제품 및 패키지 훼손, 사용 흔적이 있는 제품은 교환/반품이 불가합니다.

About
33-channel and high dynamic range charge sensitive preamplifier-shaper circuit, with sample and hold, multiplexed analog readout and calibration facilities. Parallel analogue output of all 33 pre-amplifiers. Compatible with parallel connection to 32 channels TA-ASICs.
Publications
Torii, S., et al., “Development of front-end electronics with large dynamic range for space applications.” Nuclear Physics B-Proceedings Supplements 150 (2006): 390-393, doi:10.1016/j.nuclphysbps.2004.08.047
S. Marrocchesi, P., et al. “A silicon array for cosmic-ray composition measurements in CALET.” Journal of the Physical Society of Japan 78.Suppl. A (2009): 181-183, doi:10.1143/JPSJS.78SA.181
Marrocchesi, P. S., https://www.researchgate.net/publication/253124469_Polar_balloon_flights_with_a_scaled_version_of_CALET, Memorie della Societa Astronomica Italiana 79 (2008): 829, source: SAIT
| Detectors | Multi-anode photomultiplier (MA-PMT) |
| Application | Imaging, Spectroscopy, Calorimetry |
| Number of inputs | 33 |
| Input charge range | -20 pC to +8 pC |
| Shaping time | 2 μs |
| Equivalent Noise Charge (ENC) | 5200e + 5e/pF |
| Outputs | Multiplexed pulse height and individual output per channel |
| Test and calibration | Internal calibration circuit and test channel |
| Power consumption | 3.4 mW / channel |